- Maskinbetegnelse:
- Klimaskap med fuktighet 34 liter
- Produsent:
- Weiss
- Modell:
- WKL 34/40 -40...+150°C
- Tilstand:
- svært god (brukt)
Pris og beliggenhet
- Plassering:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ring
Detaljer om tilbudet
- Annonse-ID:
- A20492700
- Referansenummer:
- 24870
- Oppdatering:
- sist oppdatert 10.11.2025
Beskrivelse
Weiss
Type: WKL 34/40
Weiss Climate Chamber, Air-Cooled
-40°C to 150°C
Chamber Volume: 34 litres
Standard feedthroughs installed:
R1 NW 50 mm
L1 NW 120 mm
Nwodpfx Agexvpp Rs Sor
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specification values for temperature tests:
Temperature range: -40 to +150 °C
Temperature variations at steady state, according to IEC 60068-3-5:
Temporal temperature fluctuation at the centre of usable space: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Maximum heat compensation: 800 W
Specification values for climate tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% RH
Temperature and humidity deviations (steady state, to IEC 60068-3-5):
Temporal temperature fluctuation at centre of usable space: ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation at centre of usable space: ± 3 to ± 5% RH
Operating data:
Test chamber lighting: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ± 10 %, 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Customer-side fuse: 16A slow-blow
Heat dissipation for air-cooled test chambers:
Max. heat discharge to environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important notice:
"The table shown in the photos is not included in the sale."
For your safety as the buyer, please note the following information!
The following procedures are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Technical data subject to change and errors excepted!)
If you have further questions, we are happy to answer them by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Type: WKL 34/40
Weiss Climate Chamber, Air-Cooled
-40°C to 150°C
Chamber Volume: 34 litres
Standard feedthroughs installed:
R1 NW 50 mm
L1 NW 120 mm
Nwodpfx Agexvpp Rs Sor
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specification values for temperature tests:
Temperature range: -40 to +150 °C
Temperature variations at steady state, according to IEC 60068-3-5:
Temporal temperature fluctuation at the centre of usable space: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Maximum heat compensation: 800 W
Specification values for climate tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% RH
Temperature and humidity deviations (steady state, to IEC 60068-3-5):
Temporal temperature fluctuation at centre of usable space: ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation at centre of usable space: ± 3 to ± 5% RH
Operating data:
Test chamber lighting: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ± 10 %, 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Customer-side fuse: 16A slow-blow
Heat dissipation for air-cooled test chambers:
Max. heat discharge to environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important notice:
"The table shown in the photos is not included in the sale."
For your safety as the buyer, please note the following information!
The following procedures are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Technical data subject to change and errors excepted!)
If you have further questions, we are happy to answer them by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Tilbyder
Merk: Registrer deg gratis eller logg inn, for å få tilgang til all informasjon.
Registrert siden: 2012
Send forespørsel
Telefon & Faks
+49 2861 ... annonser
Disse annonsene kan også være av interesse for deg.
Annonse
Mögglingen
1 301 km
Koordinat målemaskin
KEYENCEWM 3000
KEYENCEWM 3000
Annonse
Borken
964 km
Klimatisk kammer
VötschVC³ 4060
VötschVC³ 4060
Annonse
Mainz
1 169 km
Rasterelektronmikroskop (REM)
ZeissXB 350
ZeissXB 350
Annonse
Borken
964 km
Vekslende klimakammer
BinderMKF 720 E1 / E1.1
BinderMKF 720 E1 / E1.1
Annonse
Borken
964 km
Klimatisk kammer
CTSC-40/200
CTSC-40/200
Annonse
Borken
964 km
Temperatur testskap
Heraeus VötschHT 7010 -70°C bis +180°C
Heraeus VötschHT 7010 -70°C bis +180°C
Annonse
Borken
964 km
Temperaturskap
WEISSWT3- 180/40
WEISSWT3- 180/40
Annonse
Borken
964 km
High-end elementaranalyseapparat
BrukerS8 TIGER WDXRF Spektrometer
BrukerS8 TIGER WDXRF Spektrometer
Annonse
Köln
1 065 km
Skap for ren luft
HeraguardHPH 15
HeraguardHPH 15
Annonse
Borken
964 km
Klimatestkammer shakerkammer 2160 liter
WeissWK3-2200/40/5/V -40°C bis +180°C
WeissWK3-2200/40/5/V -40°C bis +180°C
Annonsen din har blitt slettet
Det har oppstått en feil