Klimaskap med fuktighet 34 literWeiss
WKL 34/40 -40...+150°C
Klimaskap med fuktighet 34 liter
Weiss
WKL 34/40 -40...+150°C
Tilstand
Brukt
Plassering
Borken 

Bilder viser
Vis kart
Data om maskinen
- Maskinbetegnelse:
- Klimaskap med fuktighet 34 liter
- Produsent:
- Weiss
- Modell:
- WKL 34/40 -40...+150°C
- Tilstand:
- svært god (brukt)
Pris og beliggenhet
- Plassering:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ring
Detaljer om tilbudet
- Annonse-ID:
- A20492700
- Referansenummer:
- 24870
- Oppdatering:
- sist oppdatert 10.11.2025
Beskrivelse
Weiss
Type: WKL 34/40
Weiss Climate Chamber, Air-Cooled
-40°C to 150°C
Chamber Volume: 34 litres
Standard feedthroughs installed:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specification values for temperature tests:
Temperature range: -40 to +150 °C
Temperature variations at steady state, according to IEC 60068-3-5:
Temporal temperature fluctuation at the centre of usable space: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Dodpfxsxvpp Rs Af Uewd
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Maximum heat compensation: 800 W
Specification values for climate tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% RH
Temperature and humidity deviations (steady state, to IEC 60068-3-5):
Temporal temperature fluctuation at centre of usable space: ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation at centre of usable space: ± 3 to ± 5% RH
Operating data:
Test chamber lighting: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ± 10 %, 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Customer-side fuse: 16A slow-blow
Heat dissipation for air-cooled test chambers:
Max. heat discharge to environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important notice:
"The table shown in the photos is not included in the sale."
For your safety as the buyer, please note the following information!
The following procedures are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Technical data subject to change and errors excepted!)
If you have further questions, we are happy to answer them by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Type: WKL 34/40
Weiss Climate Chamber, Air-Cooled
-40°C to 150°C
Chamber Volume: 34 litres
Standard feedthroughs installed:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm x Width 324 mm x Depth 300 mm
External dimensions: Height 1740 mm x Width 630 mm x Depth 970 mm
Specification values for temperature tests:
Temperature range: -40 to +150 °C
Temperature variations at steady state, according to IEC 60068-3-5:
Temporal temperature fluctuation at the centre of usable space: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Dodpfxsxvpp Rs Af Uewd
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Maximum heat compensation: 800 W
Specification values for climate tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% RH
Temperature and humidity deviations (steady state, to IEC 60068-3-5):
Temporal temperature fluctuation at centre of usable space: ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation at centre of usable space: ± 3 to ± 5% RH
Operating data:
Test chamber lighting: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ± 10 %, 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Customer-side fuse: 16A slow-blow
Heat dissipation for air-cooled test chambers:
Max. heat discharge to environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important notice:
"The table shown in the photos is not included in the sale."
For your safety as the buyer, please note the following information!
The following procedures are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Technical data subject to change and errors excepted!)
If you have further questions, we are happy to answer them by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Tilbyder
Merk: Registrer deg gratis eller logg inn, for å få tilgang til all informasjon.
Send forespørsel
Telefon & Faks
+49 2861 ... annonser
Annonsen din har blitt slettet
Det har oppstått en feil