Beskrivelse
Type: WK3-340/70
Weiss climate test chamber, water-cooled
Control panel: Touch Panel
All control and operating commands can be triggered by simply touching the function symbols on the touch panel.
Leveling feet
To compensate for uneven floors and ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Cable ports
The test chamber is equipped with feed-throughs on both the right and left sides. These allow measurement cables and test devices to be routed into the test compartment.
Standard cable port installed:
R1: nominal width 125 mm
L1: nominal width 85 mm
Volume: 335 liters
Test compartment dimensions:
Height: 750 mm, width: 580 mm, depth: 765 mm
External dimensions:
Height: 1775 mm, width: 870 mm, depth: 1600 mm
Data for temperature tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature uniformity: ±0.5 to ±1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Data for climate tests:
Temperature range: +10°C to +95°C
Dew point range: –3°C to +94°C
Humidity range: 10 to 98% RH
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature uniformity: ±0.5 to ±1 K
Temporal humidity deviation: ±1 to ±3% RH
Operational data:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A, rated power: 4.9 kW
Protection: 16 A slow-blow fuse (to be provided by customer)
Refrigerant: R-452A / R23
Weight: approx. 585 kg
Important safety information for buyers:
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Dodsxmg Sdepfx Aatowc
Condition: used
Delivery scope: (see photo)
(Technical data subject to change and errors excepted!)
We are happy to answer further questions by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Weiss climate test chamber, water-cooled
Control panel: Touch Panel
All control and operating commands can be triggered by simply touching the function symbols on the touch panel.
Leveling feet
To compensate for uneven floors and ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Cable ports
The test chamber is equipped with feed-throughs on both the right and left sides. These allow measurement cables and test devices to be routed into the test compartment.
Standard cable port installed:
R1: nominal width 125 mm
L1: nominal width 85 mm
Volume: 335 liters
Test compartment dimensions:
Height: 750 mm, width: 580 mm, depth: 765 mm
External dimensions:
Height: 1775 mm, width: 870 mm, depth: 1600 mm
Data for temperature tests:
Minimum temperature: –72°C
Maximum temperature: +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature uniformity: ±0.5 to ±1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Data for climate tests:
Temperature range: +10°C to +95°C
Dew point range: –3°C to +94°C
Humidity range: 10 to 98% RH
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature uniformity: ±0.5 to ±1 K
Temporal humidity deviation: ±1 to ±3% RH
Operational data:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A, rated power: 4.9 kW
Protection: 16 A slow-blow fuse (to be provided by customer)
Refrigerant: R-452A / R23
Weight: approx. 585 kg
Important safety information for buyers:
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Dodsxmg Sdepfx Aatowc
Condition: used
Delivery scope: (see photo)
(Technical data subject to change and errors excepted!)