Klimatestkammer 800 L, -55°C til +180°CWeiss
ClimeEvent C/800/55a/25/S 25K/min
Klimatestkammer 800 L, -55°C til +180°C
Weiss
ClimeEvent C/800/55a/25/S 25K/min
Produksjonsår
2020
Tilstand
Brukt
Plassering
Borken 

Bilder viser
Vis kart
Data om maskinen
- Maskinbetegnelse:
- Klimatestkammer 800 L, -55°C til +180°C
- Produsent:
- Weiss
- Produksjonsår:
- 2020
- Tilstand:
- svært god (brukt)
Pris og beliggenhet
- Plassering:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ring
Detaljer om tilbudet
- Annonse-ID:
- A19821050
- Referansenummer:
- 24761
- Oppdatering:
- sist oppdatert 22.08.2025
Beskrivelse
Weiss
Type: C/800/55a/25/S
Rjdpow R Rt Iefx Abcjn
Year of manufacture: 2020
Weiss Climate Test Chamber ClimeEvent, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load: Designed for a maximum payload of 250 kg
Key values for temperature tests:
Temperature range: -55 to +180°C
Temperature fluctuation over time at the center of the test space: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (to -45°C)
Maximum heat compensation: 8000 W
Key values for climatic tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % RH
Climatic performance data (extract)
Humidity range:
10 to 98 % relative humidity (RH)
Humidity deviation (over time):
At the center of the test space, in steady-state condition, depending on the climate value:
±1 to ±3 % RH
Temperature deviation (over time):
At the center of the test space, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20 % RH):
±0.5 to ±1 K
Operational data:
LED strip 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10 % 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
The chamber is equipped with a Greenmode
Weight: approx. 2050 kg
For your safety as a buyer, please note the following information!
The following procedures are carried out in advance on all chambers offered by us:
1. Function check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data and specifications subject to change and errors!)
For further questions, please feel free to contact us by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Type: C/800/55a/25/S
Rjdpow R Rt Iefx Abcjn
Year of manufacture: 2020
Weiss Climate Test Chamber ClimeEvent, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load: Designed for a maximum payload of 250 kg
Key values for temperature tests:
Temperature range: -55 to +180°C
Temperature fluctuation over time at the center of the test space: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (to -45°C)
Maximum heat compensation: 8000 W
Key values for climatic tests:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % RH
Climatic performance data (extract)
Humidity range:
10 to 98 % relative humidity (RH)
Humidity deviation (over time):
At the center of the test space, in steady-state condition, depending on the climate value:
±1 to ±3 % RH
Temperature deviation (over time):
At the center of the test space, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20 % RH):
±0.5 to ±1 K
Operational data:
LED strip 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10 % 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
The chamber is equipped with a Greenmode
Weight: approx. 2050 kg
For your safety as a buyer, please note the following information!
The following procedures are carried out in advance on all chambers offered by us:
1. Function check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data and specifications subject to change and errors!)
For further questions, please feel free to contact us by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Tilbyder
Merk: Registrer deg gratis eller logg inn, for å få tilgang til all informasjon.
Registrert siden: 2012
Send forespørsel
Telefon & Faks
+49 2861 ... annonser
Disse annonsene kan også være av interesse for deg.
Annonse
Sonsbeck
996 km
Strekkprøving maskin-universell testmaskin
Richard Hess MBV GmbHH3000-H5000TM mit Langwegextensometer
Richard Hess MBV GmbHH3000-H5000TM mit Langwegextensometer
Annonse
Sonsbeck
996 km
Strekkprøving maskin-universell testmaskin
Hegewald & PeschkeH5TMCI
Hegewald & PeschkeH5TMCI
Annonse
Sonsbeck
996 km
Universell testmaskin Strekkprøvemaskin
Richard Hess MBV GmbHUniversalprüfmaschine H3000TM
Richard Hess MBV GmbHUniversalprüfmaschine H3000TM
Annonse
Borken
964 km
Klimatisk kammer
VötschVC³ 4060
VötschVC³ 4060
Annonse
Tyskland
1 043 km
Stansemaskin
TRUMPF TC5000-1600 Big Format29000,-euro
TRUMPF TC5000-1600 Big Format29000,-euro
Annonse
Wiesbaden
1 157 km
Rockwell hardhet tester
REICHERTERBriro-Pedal
REICHERTERBriro-Pedal
Annonse
Sonsbeck
996 km
Universell testmaskin strekkprøvingsmaskin
Hegewald & PeschkeH2,5TMNI
Hegewald & PeschkeH2,5TMNI
Annonse
Borken
964 km
Korrosjonstestskap for saltspray
VLMCC 1000-FL HL V.745.672.120
VLMCC 1000-FL HL V.745.672.120
Annonse
Sonsbeck
996 km
Universell testmaskin strekkprøvingsmaskin
Hegewald & PeschkeH5TMCI
Hegewald & PeschkeH5TMCI
Annonse
Borken
964 km
Korrosjon testkammer
VLMSAL 400 V.713.062.000
VLMSAL 400 V.713.062.000
Annonsen din har blitt slettet
Det har oppstått en feil