Klimatisk testkammer temp. -70 til 180 °CWeiss explosionsgeschützt
WK-600/70 (I)-(II) 2 G EEx
Klimatisk testkammer temp. -70 til 180 °C
Weiss explosionsgeschützt
WK-600/70 (I)-(II) 2 G EEx
Tilstand
Brukt
Plassering
Borken 

Bilder viser
Vis kart
Data om maskinen
- Maskinbetegnelse:
- Klimatisk testkammer temp. -70 til 180 °C
- Produsent:
- Weiss explosionsgeschützt
- Modell:
- WK-600/70 (I)-(II) 2 G EEx
- Tilstand:
- svært god (brukt)
Pris og beliggenhet
- Plassering:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ring
Detaljer om tilbudet
- Annonse-ID:
- A18631321
- Referansenummer:
- 20744
- Oppdatering:
- sist oppdatert 04.03.2025
Beskrivelse
Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber explosion-proof)
INERTING WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Isdpfx Ajv Ewy Hoa Neap
Test Chamber Designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 litres
Cooling / heating operation: -70 to 180°C
Climate operation: 10 – 95°C
Humidity: 10...98% r.h.
Temperature change rate:
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Customer-provided fuse: 32 A slow-blow
Permissible test load:
Total rack load: 80 kg
Test chamber floor: 80 kg, insert rack: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The evaporator of the air conditioning system has been replaced)
Important safety information for buyers!
The following procedures are carried out in advance on our offered chambers:
1. Functional inspection and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, a documented test run is carried out.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in technical data and details!)
Further questions? Feel free to contact us by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber explosion-proof)
INERTING WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Isdpfx Ajv Ewy Hoa Neap
Test Chamber Designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 litres
Cooling / heating operation: -70 to 180°C
Climate operation: 10 – 95°C
Humidity: 10...98% r.h.
Temperature change rate:
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Customer-provided fuse: 32 A slow-blow
Permissible test load:
Total rack load: 80 kg
Test chamber floor: 80 kg, insert rack: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The evaporator of the air conditioning system has been replaced)
Important safety information for buyers!
The following procedures are carried out in advance on our offered chambers:
1. Functional inspection and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, a documented test run is carried out.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in technical data and details!)
Further questions? Feel free to contact us by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Send forespørsel
Telefon & Faks
+49 2861 ... annonser
Disse annonsene kan også være av interesse for deg.
Annonse
Bad Salzungen
1 078 km
Stjernesikt
Butzer - EVRESS / B2
Butzer - EVRESS / B2
Annonse
Sonsbeck
996 km
Universell testmaskin strekkprøvingsmaskin
Hegewald & PeschkeH2,5TMNI
Hegewald & PeschkeH2,5TMNI
Annonse
Borken
964 km
Korrosjonstestskap for saltspray
VLMCC 1000-FL HL V.745.672.120
VLMCC 1000-FL HL V.745.672.120
Annonse
Sonsbeck
996 km
Universell testmaskin strekkprøvingsmaskin
Hegewald & PeschkeH5TMCI
Hegewald & PeschkeH5TMCI
Annonse
Borken
964 km
Klimatestkammer 800 L, -55°C til +180°C
WeissClimeEvent C/800/55a/25/S 25K/min
WeissClimeEvent C/800/55a/25/S 25K/min
Annonse
Borken
967 km
Hvitt temperaturskap -72°C - +180°C
Weiss Temperaturschrank -72°C - +180°CWT3-340/70 335 Liter Luftgekühlt
Weiss Temperaturschrank -72°C - +180°CWT3-340/70 335 Liter Luftgekühlt
Annonse
Borken
964 km
Klimatestkammer med luftfuktighet
Weiss -72°C bis +180°CWK3-340/70
Weiss -72°C bis +180°CWK3-340/70
Annonse
Borken
964 km
Inkubator 115 liter 5 °C til 100 °C
BinderBD 115
BinderBD 115
Annonse
Borken
964 km
Temperaturtestkammer 335 liter
Vötsch-70°C bis +180°C VTS 7034-5
Vötsch-70°C bis +180°C VTS 7034-5
Annonse
Borken
964 km
Saltsprøytekammer / klimaskifteapparat
WeissSC/KWT 450
WeissSC/KWT 450
Annonsen din har blitt slettet
Det har oppstått en feil