Klimatestskap 990 literWeiss – 40…+ 180°C
WK11-1000/40 mit Zander K-MT 2
Klimatestskap 990 liter
Weiss – 40…+ 180°C
WK11-1000/40 mit Zander K-MT 2
Tilstand
Brukt
Plassering
Borken 

Bilder viser
Vis kart
Data om maskinen
Pris og beliggenhet
- Plassering:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ring
Detaljer om tilbudet
- Annonse-ID:
- A20761877
- Referansenummer:
- 24929
- Oppdatering:
- sist oppdatert 12.01.2026
Beskrivelse
Weiss
Type: WK11-1000/40
For sale is a professional Weiss Environmental Test Chamber WT-WK 1000/40 with fully automatic cold-regenerating adsorption dryer.
Gsdpfx Ahox Hxkzszsbg
The internal fixtures currently present in the test chamber can be removed if required. Due to these fixtures, the control cabinet is currently limited to a temperature range of -40 °C to +60 °C. After removal of the fixtures, the manufacturer can restore the standard temperature range of -40 °C to +180 °C, as the current fixtures are not suitable for higher temperatures.
The unit is ideal for precise temperature and humidity testing on components, assemblies, and devices. Perfect for use in industrial applications, development, quality assurance, and research environments.
Weiss Climate Test Chamber, Water-cooled
Specifications for Temperature Testing:
- Temperature range: -40°C to +60°C
- Temporal temperature fluctuation (center of usable space): ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±2.0 K
- Rate of temperature change:
- Heating: 4 K/min
- Cooling: 3 K/min
Specifications for Climatic Testing:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98 % RH
- Temporal temperature fluctuation (center of usable space): ±0.1 to ±0.3 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temporal humidity fluctuation (center of usable space): ±1 to ±3 % RH
Heat compensation:
- In the range from +25°C to +95°C
- At relative humidity up to 90%, 500 W
Humidification System Data:
- Reservoir volume: 20 L
- Water quality: Demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 µS/cm³
- Water consumption at constant +40°C, 92 % RH: 21 L/24 h
Temperature gradient (according to IEC 60068-3-5): 1 to 2 K
Test Chamber Dimensions:
- Height: 950 mm
- Width: 1100 mm
- Depth: 950 mm
External Dimensions:
- Height: 1980 mm
- Width: 1385 mm
- Depth: 1850 mm
Test chamber volume: approx. 990 liters
Rated voltage: 3/N / PE AC 400 V +10% 50 Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
For your peace of mind as a buyer, please note the following:
The following points are carried out in advance on all chambers we offer:
1. Function test and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful verification, the chambers undergo a documented test run
Condition: Used
Scope of delivery: (See image)
(Technical data subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Type: WK11-1000/40
For sale is a professional Weiss Environmental Test Chamber WT-WK 1000/40 with fully automatic cold-regenerating adsorption dryer.
Gsdpfx Ahox Hxkzszsbg
The internal fixtures currently present in the test chamber can be removed if required. Due to these fixtures, the control cabinet is currently limited to a temperature range of -40 °C to +60 °C. After removal of the fixtures, the manufacturer can restore the standard temperature range of -40 °C to +180 °C, as the current fixtures are not suitable for higher temperatures.
The unit is ideal for precise temperature and humidity testing on components, assemblies, and devices. Perfect for use in industrial applications, development, quality assurance, and research environments.
Weiss Climate Test Chamber, Water-cooled
Specifications for Temperature Testing:
- Temperature range: -40°C to +60°C
- Temporal temperature fluctuation (center of usable space): ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±2.0 K
- Rate of temperature change:
- Heating: 4 K/min
- Cooling: 3 K/min
Specifications for Climatic Testing:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98 % RH
- Temporal temperature fluctuation (center of usable space): ±0.1 to ±0.3 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temporal humidity fluctuation (center of usable space): ±1 to ±3 % RH
Heat compensation:
- In the range from +25°C to +95°C
- At relative humidity up to 90%, 500 W
Humidification System Data:
- Reservoir volume: 20 L
- Water quality: Demineralized
- pH value: 6 to 7
- Conductivity: 5 to 20 µS/cm³
- Water consumption at constant +40°C, 92 % RH: 21 L/24 h
Temperature gradient (according to IEC 60068-3-5): 1 to 2 K
Test Chamber Dimensions:
- Height: 950 mm
- Width: 1100 mm
- Depth: 950 mm
External Dimensions:
- Height: 1980 mm
- Width: 1385 mm
- Depth: 1850 mm
Test chamber volume: approx. 990 liters
Rated voltage: 3/N / PE AC 400 V +10% 50 Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R 404A
Weight: 840 kg
For your peace of mind as a buyer, please note the following:
The following points are carried out in advance on all chambers we offer:
1. Function test and replacement of necessary components
2. Refilling with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful verification, the chambers undergo a documented test run
Condition: Used
Scope of delivery: (See image)
(Technical data subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Tilbyder
Merk: Registrer deg gratis eller logg inn, for å få tilgang til all informasjon.
Registrert siden: 2012
Send forespørsel
Telefon & Faks
+49 2861 ... annonser
Disse annonsene kan også være av interesse for deg.
Annonse
Goudriaan
980 km
Slåmaskin
Boxer AgriMaster 175
Boxer AgriMaster 175
Annonsen din har blitt slettet
Det har oppstått en feil