Beskrivelse
Zwick / Roell
Type: Mflow
Application Range
As testing volumes increase, so does the need for a higher degree of automation (compared to the Cflow). The Mflow is a modularly expandable device that allows you to determine both melt mass-flow rate and melt volume-flow rate. The Mflow melt flow tester, in its basic version, is designed for MFR tests according to Method A and can be upgraded for MVR tests according to Method B. The following standards can be tested:
• Methods A and B in accordance with ISO 1133
• Methods A, B, and C in accordance with ASTM D 1238
• ASTM D 3364
• JIS K 7210
Optionally, the Mflow can be expanded, for example, with pneumatic weight lifting (with and without cleaning function) or with weight addition.
The Mflow can be operated either as a standalone machine via a modern touch display, or with ZwickRoell testing software on a PC.
Technical Data
Test load: 0.325 - 21.6 kg
Compressed air, oiled, dry: 6 - 10 bar
Dimensions
Height: 510 mm
Width: 360 mm
Depth: 419 mm
Weight approx.: 43 kg
Test temperature: +50°C to +450°C
Display: Capacitive touch display
Temperature display resolution: < 0.1 K
Number of storable parameter sets: >100
Hedstq Em Topfx Adkefp
Temperature accuracy in the 0 - 75 mm area above the die within 50°C to 450°C: < 0.3 K
Time Measurement
Error margin (Method A): ± 0.02 (with automatic cutting device)
Error margin (Method B): ± 0.01
Travel Measurement
Error margin (Method B): ±0.02 mm (ISO 1133) / ±0.4% of 6.25 mm (ASTM D 1238)
Resolution: < 0.005
Multi-device operation on one PC:
Available RAM, min.: 1.54 GB
Clock speed: 3 GHz
Number of connectable Mflow testers per PC: 6
Power supply: 220 - 240 V, 1L/PE/N
Power consumption: 2.6 A
Mains frequency: 50/60 Hz
Software version: V4.2
Year of construction: 2021
Condition: used
Scope of supply: (see image)
(Specifications and technical data are subject to change and error!)
We will be happy to answer any further questions by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Type: Mflow
Application Range
As testing volumes increase, so does the need for a higher degree of automation (compared to the Cflow). The Mflow is a modularly expandable device that allows you to determine both melt mass-flow rate and melt volume-flow rate. The Mflow melt flow tester, in its basic version, is designed for MFR tests according to Method A and can be upgraded for MVR tests according to Method B. The following standards can be tested:
• Methods A and B in accordance with ISO 1133
• Methods A, B, and C in accordance with ASTM D 1238
• ASTM D 3364
• JIS K 7210
Optionally, the Mflow can be expanded, for example, with pneumatic weight lifting (with and without cleaning function) or with weight addition.
The Mflow can be operated either as a standalone machine via a modern touch display, or with ZwickRoell testing software on a PC.
Technical Data
Test load: 0.325 - 21.6 kg
Compressed air, oiled, dry: 6 - 10 bar
Dimensions
Height: 510 mm
Width: 360 mm
Depth: 419 mm
Weight approx.: 43 kg
Test temperature: +50°C to +450°C
Display: Capacitive touch display
Temperature display resolution: < 0.1 K
Number of storable parameter sets: >100
Hedstq Em Topfx Adkefp
Temperature accuracy in the 0 - 75 mm area above the die within 50°C to 450°C: < 0.3 K
Time Measurement
Error margin (Method A): ± 0.02 (with automatic cutting device)
Error margin (Method B): ± 0.01
Travel Measurement
Error margin (Method B): ±0.02 mm (ISO 1133) / ±0.4% of 6.25 mm (ASTM D 1238)
Resolution: < 0.005
Multi-device operation on one PC:
Available RAM, min.: 1.54 GB
Clock speed: 3 GHz
Number of connectable Mflow testers per PC: 6
Power supply: 220 - 240 V, 1L/PE/N
Power consumption: 2.6 A
Mains frequency: 50/60 Hz
Software version: V4.2
Year of construction: 2021
Condition: used
Scope of supply: (see image)
(Specifications and technical data are subject to change and error!)
We will be happy to answer any further questions by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Tilbyder
Merk: Registrer deg gratis eller logg inn, for å få tilgang til all informasjon.
Registrert siden: 2012
Send forespørsel
Telefon & Faks
+49 2861 ... annonser
Annonsen din har blitt slettet
Det har oppstått en feil