Klimakammer med luftfuktighet 34 literWeiss
WKL 34/60 -60°C bis 150°C
Klimakammer med luftfuktighet 34 liter
Weiss
WKL 34/60 -60°C bis 150°C
Tilstand
Brukt
Plassering
Borken 

Data om maskinen
- Maskinbetegnelse:
- Klimakammer med luftfuktighet 34 liter
- Produsent:
- Weiss
- Modell:
- WKL 34/60 -60°C bis 150°C
- Tilstand:
- svært god (brukt)
Pris og beliggenhet
- Plassering:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ring
Detaljer om tilbudet
- Annonse-ID:
- A16211179
- Referansenummer:
- 24134
- Oppdatering:
- sist oppdatert 15.11.2024
Beskrivelse
Weiss
Type: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
-60°C to +150°C
Chamber Volume: 34 liters
Standard feedthroughs installed:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Technical specifications for temperature tests:
Temperature range: -60 to +150°C
Temperature deviations (stabilized, according to IEC 60068-3-5):
Temporal temperature fluctuation at center of usable space: ±0.3 to ±1 K; ±1 to ±2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Heat compensation max.: 550 W
Technical specifications for climate tests:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Ncodpfstr Dinjx Akaot
Temperature and humidity deviations (stabilized, according to IEC 60068-3-5):
Temporal temperature fluctuation at center of usable space: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation at center of usable space: ±3 to ±5% RH
Operating data:
Test chamber lighting: Halogen bulb, 12V, 20W
Rated voltage: 1/N / PE AC 230V ±10% 50Hz
Rated power: 2.5 kW
Rated current: 11 A
Recommended fuse: 16A slow-blow
Heat dissipation for air-cooled chambers:
Max. heat output to environment: 1700 W
Refrigerants: R-452A / R23
Weight: 140 kg
Important Notice for Buyers!
For your safety, the following steps are performed on all our offered chambers before sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful verification, the chamber undergoes a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data and specifications!)
We are happy to answer any further questions by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Type: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
-60°C to +150°C
Chamber Volume: 34 liters
Standard feedthroughs installed:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Technical specifications for temperature tests:
Temperature range: -60 to +150°C
Temperature deviations (stabilized, according to IEC 60068-3-5):
Temporal temperature fluctuation at center of usable space: ±0.3 to ±1 K; ±1 to ±2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Heat compensation max.: 550 W
Technical specifications for climate tests:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Ncodpfstr Dinjx Akaot
Temperature and humidity deviations (stabilized, according to IEC 60068-3-5):
Temporal temperature fluctuation at center of usable space: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 (temperature gradient): 1 to 3
Temporal humidity fluctuation at center of usable space: ±3 to ±5% RH
Operating data:
Test chamber lighting: Halogen bulb, 12V, 20W
Rated voltage: 1/N / PE AC 230V ±10% 50Hz
Rated power: 2.5 kW
Rated current: 11 A
Recommended fuse: 16A slow-blow
Heat dissipation for air-cooled chambers:
Max. heat output to environment: 1700 W
Refrigerants: R-452A / R23
Weight: 140 kg
Important Notice for Buyers!
For your safety, the following steps are performed on all our offered chambers before sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful verification, the chamber undergoes a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data and specifications!)
We are happy to answer any further questions by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Send forespørsel
Telefon & Faks
+49 2861 ... annonser
Disse annonsene kan også være av interesse for deg.
Annonse
Chelles
1 342 km
Digital trykkmaskin
Konica MinoltaAccurionPress C2070
Konica MinoltaAccurionPress C2070
Annonse
Emskirchen
1 224 km
Sammenleggbare maskiner
StahlT 52.3/4-T-F
StahlT 52.3/4-T-F
Annonse
Winkelhaid
1 247 km
BANDEROLING MASKIN
AkebonoOB-301
AkebonoOB-301
Annonse
Emskirchen
1 224 km
Plotter
HP5000
HP5000
Annonse
Helmstedt
929 km
Inserters
Winkler + Dünnebier (W+D)Buhrs BB 300
Winkler + Dünnebier (W+D)Buhrs BB 300
Annonse
Tallinn
916 km
Plasseringsmaskin / P&P
YAMAHAYSM20-2
YAMAHAYSM20-2
Annonse
Metzingen
1 329 km
Koordinatmålemaskin
WENZELLH 54 CNC
WENZELLH 54 CNC
Annonse
Zuchwil
1 478 km
Retort varmebehandling ovn
MUT360/400-1150
MUT360/400-1150
Annonse
Berlin
939 km
Projeksjonssveisemaskin
DalexPMS 11-4
DalexPMS 11-4
Annonse
Győr
1 540 km
Symaskin
PFAFF335
PFAFF335
Annonsen din har blitt slettet
Det har oppstått en feil