Data om maskinen
- Maskinbetegnelse:
- Differensiell skanningskalorimeter
- Produsent:
- Perkin Elmer
- Modell:
- DSC 8000, N5340524
- Tilstand:
- brukt
Pris og beliggenhet
EXW Fast pris pluss MVA
€ 29 750
- Plassering:
- Heilbronner Str. 22, 01189 Dresden, Deutschland

Ring
Detaljer om tilbudet
- Annonse-ID:
- A21283042
- Referansenummer:
- LW43630
- Oppdatering:
- sist oppdatert 20.02.2026
Beskrivelse
Perkin Elmer instruments Differential Scanning Calorimeter with cooling, DSC 8000, N5340524
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation. Perkin Elmer DSC 8000 equipped with Intracooler 2 for precise heat flow measurements from approx. –70 °C to 750 °C, featuring high sensitivity and rapid thermal response.
General Device Specifications
DSC Type: Dual-furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed, platinum resistance thermometers
Temperature Performance
Standard Temperature Range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Dcedpfxoyluics Ab Sof
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and rapid response due to low-mass furnace design
Outstanding baseline stability and temperature accuracy
Gas and Atmosphere Control
Two controlled gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photo calorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power 400 VA
Accessories
Polyscience Intracooler 2 cooling system
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells UV/photo calorimeter accessories
IEC power connector
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on device condition:
Without software/PC
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation. Perkin Elmer DSC 8000 equipped with Intracooler 2 for precise heat flow measurements from approx. –70 °C to 750 °C, featuring high sensitivity and rapid thermal response.
General Device Specifications
DSC Type: Dual-furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed, platinum resistance thermometers
Temperature Performance
Standard Temperature Range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Dcedpfxoyluics Ab Sof
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and rapid response due to low-mass furnace design
Outstanding baseline stability and temperature accuracy
Gas and Atmosphere Control
Two controlled gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photo calorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power 400 VA
Accessories
Polyscience Intracooler 2 cooling system
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells UV/photo calorimeter accessories
IEC power connector
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on device condition:
Without software/PC
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Tilbyder
Merk: Registrer deg gratis eller logg inn, for å få tilgang til all informasjon.
Registrert siden: 2014
97 Annonser på nett
Send forespørsel
Telefon & Faks
+49 351 8... annonser
Disse annonsene kan også være av interesse for deg.
Annonse
Hannover
900 km
Desktop Metal Studio System II
Desktop MetalStudio System II
Desktop MetalStudio System II
Annonse
Borken
964 km
10°C til +250°C / 749 liter
Memmert Universal - WärmeschrankUFP 800
Memmert Universal - WärmeschrankUFP 800
Annonse
Wald
1 396 km
Universalskap Varmeovn Varmeskaps
MemmertULP 600
MemmertULP 600
Annonse
Spania
1 230 km
DESKTOP METAL Metal Studio 2
DESKTOP METALMetal Studio 2
DESKTOP METALMetal Studio 2
Annonsen din har blitt slettet
Det har oppstått en feil