Differensiell skanningskalorimeterPerkin Elmer
DSC 8000, N5340524
Differensiell skanningskalorimeter
Perkin Elmer
DSC 8000, N5340524
EXW Fast pris pluss MVA
€ 29 750
Tilstand
Brukt
Plassering
Dresden 

Data om maskinen
- Maskinbetegnelse:
- Differensiell skanningskalorimeter
- Produsent:
- Perkin Elmer
- Modell:
- DSC 8000, N5340524
- Tilstand:
- brukt
Pris og beliggenhet
EXW Fast pris pluss MVA
€ 29 750
- Plassering:
- Heilbronner Str. 22, 01189 Dresden, Deutschland

Ring
Detaljer om tilbudet
- Annonse-ID:
- A21283042
- Referansenummer:
- LW43630
- Oppdatering:
- sist oppdatert 20.02.2026
Beskrivelse
Perkin Elmer instruments Differential Scanning Calorimeter with cooling, DSC 8000, N5340524
Hsdpfsyluicex Ahbjn
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation. Perkin Elmer DSC 8000 equipped with Intracooler 2 for precise heat flow measurements from approx. –70 °C to 750 °C, featuring high sensitivity and rapid thermal response.
General Device Specifications
DSC Type: Dual-furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed, platinum resistance thermometers
Temperature Performance
Standard Temperature Range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and rapid response due to low-mass furnace design
Outstanding baseline stability and temperature accuracy
Gas and Atmosphere Control
Two controlled gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photo calorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power 400 VA
Accessories
Polyscience Intracooler 2 cooling system
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells UV/photo calorimeter accessories
IEC power connector
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on device condition:
Without software/PC
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Hsdpfsyluicex Ahbjn
Model: DSC8000
Type: N5340524
Condition: Used
General:
Dual-furnace differential scanning calorimeter with power compensation. Perkin Elmer DSC 8000 equipped with Intracooler 2 for precise heat flow measurements from approx. –70 °C to 750 °C, featuring high sensitivity and rapid thermal response.
General Device Specifications
DSC Type: Dual-furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed, platinum resistance thermometers
Temperature Performance
Standard Temperature Range: approx. –180 °C to 750 °C (with suitable cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and rapid response due to low-mass furnace design
Outstanding baseline stability and temperature accuracy
Gas and Atmosphere Control
Two controlled gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Power supply connection
Accessory ports (e.g., autosampler, high-pressure cell, UV/photo calorimeter module)
Temperature calibration interface
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power 400 VA
Accessories
Polyscience Intracooler 2 cooling system
Norgren gas pressure regulator with gauges for external gas supply
Autosampler with 96 positions
High-pressure DSC cells UV/photo calorimeter accessories
IEC power connector
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on device condition:
Without software/PC
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Tilbyder
Merk: Registrer deg gratis eller logg inn, for å få tilgang til all informasjon.
Sist pålogget: forrige uke
Registrert siden: 2014
99 Annonser på nett
Send forespørsel
Telefon & Faks
+49 351 8... annonser
Disse annonsene kan også være av interesse for deg.
Annonse
Borken
964 km
Termisk analyse – Laboratorieutstyr
Mettler ToledoTGA/DSC 1 STAR
Mettler ToledoTGA/DSC 1 STAR
Annonse
Borken
964 km
Universaltetestskap +20 °C til +300 °C
MemmertUF 450plus
MemmertUF 450plus
Annonse
Tyskland
1 043 km
Varmeskap
BinderED 400/KBF 115
BinderED 400/KBF 115
Annonse
Spania
1 230 km
DESKTOP METAL Metal Studio 2
DESKTOP METALMetal Studio 2
DESKTOP METALMetal Studio 2
Annonse
Wald
1 396 km
Universalskap Varmeovn Varmeskaps
MemmertULP 600
MemmertULP 600
Annonse
Wald
1 396 km
Tørkeskap, inkubator, varmeskap
BinderED 240/E2
BinderED 240/E2
Annonsen din har blitt slettet
Det har oppstått en feil






































































