Pulsgenerator for isolasjonstestGBS Elektronik
rev3 Isolationstests bis 6nF
Pulsgenerator for isolasjonstest
GBS Elektronik
rev3 Isolationstests bis 6nF
VB pluss MVA
€ 3 780
Tilstand
Brukt
Plassering
Borken 

Bilder viser
Vis kart
Data om maskinen
- Maskinbetegnelse:
- Pulsgenerator for isolasjonstest
- Produsent:
- GBS Elektronik
- Modell:
- rev3 Isolationstests bis 6nF
- Tilstand:
- nesten som ny (brukt)
Pris og beliggenhet
VB pluss MVA
€ 3 780
- Plassering:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Ring
Detaljer om tilbudet
- Annonse-ID:
- A17569468
- Referansenummer:
- 21007
- Oppdatering:
- sist oppdatert 05.08.2025
Beskrivelse
GBS Test Pulse Rev3 Pulse Generator for Long-Term Insulation Tests
The Prüfpuls setup is designed for long-term insulation testing on test specimens with up to 6 nF capacitance.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200Hz.
· Sine wave pulse width modulation 16-24kHz via full-bridge.
· Converter voltage adjustable from 0-600V, Imax=2.6A, maximum power 1.3kW
· Pulse current limitation 110A (cut-off threshold)
Pulse Transformer – Control
· Controlled via full-bridge
· Full-bridge power supply adjustable 0-1000V, max. 1.3A.
· Pulse current limitation 100A (cut-off threshold).
· Pulse width 20-120μs, nominal 94μs, adjustable
· 2 selectable series inductances 150μH, 300μH, to adapt pulse width and rise times to load capacitance and voltage.
· Pulse repetition rate 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating depending on the polarity of the sine signal.
· Cosine-shaped pulse at transformer output
Pulse Transformer Cascade
· Output transformers in 5-stage cascaded configuration.
· Total transformation ratio selectable via taps: 1:7.7, 1:10, or 1:15.
· Maximum output voltage 15kV for possible load capacitances of: * 6nF with a pulse width of 73μs at a repetition rate of 2.5kHz * 10nF with a pulse width of 103μs at a repetition rate of 1.25kHz
· 1:1000 voltage divider in parallel.
Fjdpfou Egz Rex Af Rspr
· Overvoltage protection at approx. 20-23 kV via parallel spark gaps
· Thermistor for over-temperature detection in the first transformer stage.
· Ground-side current measuring socket 100 mV/A.
Qgqsbmp2
Breakdown Detection, Testing
· If the maximum bridge currents for the transformer control or the maximum currents of the bridge power supplies are exceeded, high voltage is switched off.
· The device features a resettable hour meter to record the test duration.
Manufacturer price approx. €59,500
More products – new and used – can be found in our shop!
International shipping costs on request!
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
The Prüfpuls setup is designed for long-term insulation testing on test specimens with up to 6 nF capacitance.
Converter for High-Voltage Test Transformer
· Internal sine wave generator: 50-200Hz.
· Sine wave pulse width modulation 16-24kHz via full-bridge.
· Converter voltage adjustable from 0-600V, Imax=2.6A, maximum power 1.3kW
· Pulse current limitation 110A (cut-off threshold)
Pulse Transformer – Control
· Controlled via full-bridge
· Full-bridge power supply adjustable 0-1000V, max. 1.3A.
· Pulse current limitation 100A (cut-off threshold).
· Pulse width 20-120μs, nominal 94μs, adjustable
· 2 selectable series inductances 150μH, 300μH, to adapt pulse width and rise times to load capacitance and voltage.
· Pulse repetition rate 0.1 – 2.5 kHz, adjustable.
· Polarity: Adjustable to positive, negative, or alternating depending on the polarity of the sine signal.
· Cosine-shaped pulse at transformer output
Pulse Transformer Cascade
· Output transformers in 5-stage cascaded configuration.
· Total transformation ratio selectable via taps: 1:7.7, 1:10, or 1:15.
· Maximum output voltage 15kV for possible load capacitances of: * 6nF with a pulse width of 73μs at a repetition rate of 2.5kHz * 10nF with a pulse width of 103μs at a repetition rate of 1.25kHz
· 1:1000 voltage divider in parallel.
Fjdpfou Egz Rex Af Rspr
· Overvoltage protection at approx. 20-23 kV via parallel spark gaps
· Thermistor for over-temperature detection in the first transformer stage.
· Ground-side current measuring socket 100 mV/A.
Qgqsbmp2
Breakdown Detection, Testing
· If the maximum bridge currents for the transformer control or the maximum currents of the bridge power supplies are exceeded, high voltage is switched off.
· The device features a resettable hour meter to record the test duration.
Manufacturer price approx. €59,500
More products – new and used – can be found in our shop!
International shipping costs on request!
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Tilbyder
Merk: Registrer deg gratis eller logg inn, for å få tilgang til all informasjon.
Registrert siden: 2008
Send forespørsel
Telefon & Faks
+49 2862 ... annonser
Disse annonsene kan også være av interesse for deg.
Annonse
Kolbuszowa
1 410 km
Plastforedlingsmaskin
Koltex Plastic Recycling SystemsXR 8
Koltex Plastic Recycling SystemsXR 8
Annonsen din har blitt slettet
Det har oppstått en feil


































