Temperatur testskapCTS
        TSR-30/1000    
 Temperatur testskap
CTS
        TSR-30/1000    
            Tilstand        
            Brukt                    
            Plassering        
                                                Borken                                            

 Bilder viser            
 Vis kart            
Data om maskinen
Pris og beliggenhet
- Plassering:
 -             Einsteinstraße 8a, 46325 Borken, DE                

 
 Ring            
Detaljer om tilbudet
- Annonse-ID:
 - A14926978
 
- Referansenummer:
 - 23988
 
- Oppdatering:
 - sist oppdatert 15.11.2024
 
Beskrivelse
        CTS
Type: TSR-30/1000
Water-cooled
The CTS cabinet series type designation is composed as follows:
For example: Type TSR-30/1000
1) T stands for: Temperature
2) S stands for: Stress Screening
3) R stands for: Remote conditioning
4) -30 stands for: lower temperature of -30°C
5) 1000 stands for: 1000 liters test chamber volume
Technical data:
A) TSR-30/1000 base unit without hose connections,
i.e., for use as a standalone temperature test chamber
Temperature tests:
Temperature range: -40°C to +180°C
Final temperature: -45°C
Temperature deviation: ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating: 6.0 K/min
Cooling: 5.0 K/min
Heat emission:
approx. 5000 W at +20°C
approx. 4200 W at 0°C
approx. 3000 W at -20°C
Bledpfx Asrivfcofqep
Technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, without heat radiation, and without additional equipment.
Airflow volume: approx. 2000 m³/h
B) TSR-30/1000 base unit with hose connections,
for connection to an external user-provided test space
Temperature tests:
Temperature range: -30°C to +170°C
Temperature deviation: ≤ ±0.1 to 0.5 K over time
Average temperature change rate, measured in closed-loop circuit:
Heating: 4.0 K/min
Cooling: 4.0 K/min
In the range from +150°C to -10°C
Technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, without heat radiation, and without additional equipment, measured in closed-loop circuit.
Attention: The external test chamber provided on-site must be completely sealed and adequately insulated; any ports must be optimally sealed on-site.
Dimensions:
Test volume: 1000 liters
Recirculating air connection: Ø 200 mm
Internal dimensions (H x W x D): 900 x 1000 x 1100 mm
External dimensions (H x W x D): 1950 x 1270 x 2245 mm
Technical Specifications:
Refrigeration unit:
Water-cooled, low-noise, fully hermetic
Stepless power adaptation via electronic monitoring and control system
Environmentally friendly refrigerant R404A
Door:
Fully opening door, left-hand hinge
One-hand operation, lockable
Insert rack:
Stainless steel, support surface 970 x 980 mm
Load per rack max. 35 kg
Total load with maximum racking 100 kg
Test chamber illumination: Halogen lamp 20 W, 12 V
Control:
- 32 Bit controller
- LCD operating panel
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 13.3 kW
Protection class: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 850 kg
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functional testing and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See image)
(Misprints and technical data subject to change!)
We are happy to answer further questions by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Type: TSR-30/1000
Water-cooled
The CTS cabinet series type designation is composed as follows:
For example: Type TSR-30/1000
1) T stands for: Temperature
2) S stands for: Stress Screening
3) R stands for: Remote conditioning
4) -30 stands for: lower temperature of -30°C
5) 1000 stands for: 1000 liters test chamber volume
Technical data:
A) TSR-30/1000 base unit without hose connections,
i.e., for use as a standalone temperature test chamber
Temperature tests:
Temperature range: -40°C to +180°C
Final temperature: -45°C
Temperature deviation: ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating: 6.0 K/min
Cooling: 5.0 K/min
Heat emission:
approx. 5000 W at +20°C
approx. 4200 W at 0°C
approx. 3000 W at -20°C
Bledpfx Asrivfcofqep
Technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, without heat radiation, and without additional equipment.
Airflow volume: approx. 2000 m³/h
B) TSR-30/1000 base unit with hose connections,
for connection to an external user-provided test space
Temperature tests:
Temperature range: -30°C to +170°C
Temperature deviation: ≤ ±0.1 to 0.5 K over time
Average temperature change rate, measured in closed-loop circuit:
Heating: 4.0 K/min
Cooling: 4.0 K/min
In the range from +150°C to -10°C
Technical data refer to an ambient temperature of +25°C, rated voltage 400V, without test specimen, without heat radiation, and without additional equipment, measured in closed-loop circuit.
Attention: The external test chamber provided on-site must be completely sealed and adequately insulated; any ports must be optimally sealed on-site.
Dimensions:
Test volume: 1000 liters
Recirculating air connection: Ø 200 mm
Internal dimensions (H x W x D): 900 x 1000 x 1100 mm
External dimensions (H x W x D): 1950 x 1270 x 2245 mm
Technical Specifications:
Refrigeration unit:
Water-cooled, low-noise, fully hermetic
Stepless power adaptation via electronic monitoring and control system
Environmentally friendly refrigerant R404A
Door:
Fully opening door, left-hand hinge
One-hand operation, lockable
Insert rack:
Stainless steel, support surface 970 x 980 mm
Load per rack max. 35 kg
Total load with maximum racking 100 kg
Test chamber illumination: Halogen lamp 20 W, 12 V
Control:
- 32 Bit controller
- LCD operating panel
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 13.3 kW
Protection class: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 850 kg
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functional testing and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See image)
(Misprints and technical data subject to change!)
We are happy to answer further questions by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Tilbyder
            Merk:        Registrer deg gratis eller logg inn, for å få tilgang til all informasjon.    
Registrert siden: 2012
Send forespørsel
Telefon & Faks
                            +49 2861 ... annonser                
            Annonsen din har blitt slettet            
            Det har oppstått en feil            