Temperaturkammer 2000 literCTS
T-40/2000 -40°C bis +180°C
Temperaturkammer 2000 liter
CTS
T-40/2000 -40°C bis +180°C
Tilstand
Brukt
Plassering
Borken 

Data om maskinen
- Maskinbetegnelse:
- Temperaturkammer 2000 liter
- Produsent:
- CTS
- Modell:
- T-40/2000 -40°C bis +180°C
- Tilstand:
- svært god (brukt)
Pris og beliggenhet
- Plassering:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Ring
Detaljer om tilbudet
- Annonse-ID:
- A22215232
- Referansenummer:
- 24329
- Oppdatering:
- sist oppdatert 26.06.2026
Beskrivelse
CTS
Type: T-40/2000
Air-Cooled Temperature Test Chamber
Technical Specifications:
Cooling unit:
Air-cooled, low-noise, fully hermetic with stepless power adjustment via electronic monitoring and control system, environmentally friendly refrigerant R404A
Door:
Full-opening door, hinge left, one-hand operation, lockable.
Tray rack:
Stainless steel, support surface 970 x 980 + 500 mm
Max. load per rack 35 kg
Max. total load with full rack placement 100 kg
Test Chamber Lighting: 3x halogen lamp 20 W, 12 V
Control:
32-bit controller
LCD control panel
Digital display of set and actual values
Numeric entry for setpoints
Plain text error messages
RS 232 interface
Free switching channels for customer-side test item activation
Temperature range: -40°C to +180°C
Rated voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Rated current: 17.2 A
Compressor: TFH2516Z
Pipe leadthrough NW 50
Control panel window: 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature testing:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating: 2.5 K/min
Cooling: 1.5 K/min
Thermal radiation:
Approx. 2500 W at +20°C
Approx. 2100 W at 0°C
Approx. 1500 W at -20°C
Technical data refer to ambient temperature of +25°C, rated voltage 400V, without test specimen, without irradiation and without additional equipment.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: Height 900, Width 975, Depth 2200 mm
External dimensions: Height 1950, Width 1290, Depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain: non-pressurized, R 1/2" female thread
Sound pressure level (measured according to DIN EN ISO 3744 at a distance of 1m from the front): < 55 dB(A)
Weight: approx. 1200 kg
Important information for you as a buyer!
The following points are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new refrigerant fill in compliance with legal regulations
3. Leak test with certificate
Bjdpfxozg Twaj Apmjdd
4. After successful review, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data!)
We are happy to answer further questions by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Type: T-40/2000
Air-Cooled Temperature Test Chamber
Technical Specifications:
Cooling unit:
Air-cooled, low-noise, fully hermetic with stepless power adjustment via electronic monitoring and control system, environmentally friendly refrigerant R404A
Door:
Full-opening door, hinge left, one-hand operation, lockable.
Tray rack:
Stainless steel, support surface 970 x 980 + 500 mm
Max. load per rack 35 kg
Max. total load with full rack placement 100 kg
Test Chamber Lighting: 3x halogen lamp 20 W, 12 V
Control:
32-bit controller
LCD control panel
Digital display of set and actual values
Numeric entry for setpoints
Plain text error messages
RS 232 interface
Free switching channels for customer-side test item activation
Temperature range: -40°C to +180°C
Rated voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Rated current: 17.2 A
Compressor: TFH2516Z
Pipe leadthrough NW 50
Control panel window: 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature testing:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5
Heating: 2.5 K/min
Cooling: 1.5 K/min
Thermal radiation:
Approx. 2500 W at +20°C
Approx. 2100 W at 0°C
Approx. 1500 W at -20°C
Technical data refer to ambient temperature of +25°C, rated voltage 400V, without test specimen, without irradiation and without additional equipment.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: Height 900, Width 975, Depth 2200 mm
External dimensions: Height 1950, Width 1290, Depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain: non-pressurized, R 1/2" female thread
Sound pressure level (measured according to DIN EN ISO 3744 at a distance of 1m from the front): < 55 dB(A)
Weight: approx. 1200 kg
Important information for you as a buyer!
The following points are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new refrigerant fill in compliance with legal regulations
3. Leak test with certificate
Bjdpfxozg Twaj Apmjdd
4. After successful review, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data!)
We are happy to answer further questions by phone.
Annonsen ble oversatt automatisk. Oversettelsesfeil kan forekomme.
Send forespørsel
Telefon & Faks
+49 2861 ... annonser
Annonsen din har blitt slettet
Det har oppstått en feil