Triple Quadrupole LC/MS System with PCAgilent
G6410B
Triple Quadrupole LC/MS System with PC
Agilent
G6410B
EXW Fast pris pluss MVA
15 000 €
Tilstand
Brukt
(fullt funksjonell)
Plassering
Töltéstava 

Grunnleggende data
- Maskinbetegnelse:
- Triple Quadrupole LC/MS System with PC
- Produsent:
- Agilent
- Modell:
- G6410B
- Tilstand:
- brukt
- Funksjonalitet:
- fullt funksjonell
Pris og beliggenhet
EXW Fast pris pluss MVA
15 000 €
- Plassering:
- 0184/3. Hrsz, 9086 Töltéstava, Hungary

Ring
Detaljer om tilbudet
- Annonse-ID:
- A23089461
- Oppdatering:
- sist oppdatert 20.10.2026
Beskrivelse
Core Analytical Performance
• Mass Range: m/z 15 – 1,650
• Scan Rate: 5,200 atomic mass units per second (u/sec)
• Mass Accuracy: 0.1 u across the entire mass range
• Mass Stability: < 0.1 u over a 24-hour period
• Dynamic Range: > 6.5 × 10⁶
• Mass Resolution: Three user-selectable settings (Full Width at Half Maximum):
• Unit: 0.7 u
• Wide: 1.2 u
• Widest: 2.5 u
Ionization & Hardware Configuration
• Supported Ionization Sources: Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), Nanospray with HPLC-Chip Cube MS interface, and Multimode source (simultaneous ESI and APCI).
• Collision Cell: High-pressure, hexapole geometry equipped with linear acceleration to eliminate cross-talk and optimize fragmentation.
• Scan Modes: MS scan, MS/MS Product Ion scan, Multiple Reaction Monitoring (MRM), Precursor Ion scan, Neutral Loss/Gain scan, and Selected Ion Monitoring (SIM).
• Polarity Switching: Fast positive/negative switching programmed by time segments.
• Vacuum System: One triple-stage turbomolecular pump backed by a standard mechanical foreline roughing pump.
Physical & Utility Requirements
• Dimensions: Approximately 18.5" H × 43.5" W × 26" D (47 cm × 111 cm × 66 cm)
• Weight: ~236.5 lbs (107.5 kg)
Itodpfx Ao Aaylzskxjn
• Power Supply: 200 – 240 VAC, Single-phase, max consumption around 2700–2850 VA
Good working condition. Please check out our other listings as well.
• Mass Range: m/z 15 – 1,650
• Scan Rate: 5,200 atomic mass units per second (u/sec)
• Mass Accuracy: 0.1 u across the entire mass range
• Mass Stability: < 0.1 u over a 24-hour period
• Dynamic Range: > 6.5 × 10⁶
• Mass Resolution: Three user-selectable settings (Full Width at Half Maximum):
• Unit: 0.7 u
• Wide: 1.2 u
• Widest: 2.5 u
Ionization & Hardware Configuration
• Supported Ionization Sources: Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), Nanospray with HPLC-Chip Cube MS interface, and Multimode source (simultaneous ESI and APCI).
• Collision Cell: High-pressure, hexapole geometry equipped with linear acceleration to eliminate cross-talk and optimize fragmentation.
• Scan Modes: MS scan, MS/MS Product Ion scan, Multiple Reaction Monitoring (MRM), Precursor Ion scan, Neutral Loss/Gain scan, and Selected Ion Monitoring (SIM).
• Polarity Switching: Fast positive/negative switching programmed by time segments.
• Vacuum System: One triple-stage turbomolecular pump backed by a standard mechanical foreline roughing pump.
Physical & Utility Requirements
• Dimensions: Approximately 18.5" H × 43.5" W × 26" D (47 cm × 111 cm × 66 cm)
• Weight: ~236.5 lbs (107.5 kg)
Itodpfx Ao Aaylzskxjn
• Power Supply: 200 – 240 VAC, Single-phase, max consumption around 2700–2850 VA
Good working condition. Please check out our other listings as well.